Table of Contents

For system integrators in mobile machinery, engineering cost is measured not only in hardware price, but in engineering hours.

Each new HMI platform introduces questions:

  • Do engineers need to learn a proprietary API?

  • Can logic be reused across machine variants?

  • Will the display remain maintainable over a 5–10 year lifecycle?

This is where CODESYS-based CAN bus displays have gained traction.
By combining a standardized software environment with sufficient processing capability, the display evolves from a passive interface into a programmable system node within the machine architecture.

This article explains how CODESYS 3.5 on CAN bus displays benefits OEM system integrators, from development efficiency to long-term maintenance.

Why System Integrators Prioritize Software Ecosystem

System integrators rarely optimize for a single project.
Instead, they optimize for:

  • Reusability

  • Predictability

  • Maintainability across platforms

Displays that rely on proprietary tools or undocumented APIs increase risk and slow delivery.
In contrast, IEC 61131-3–based environments reduce friction when projects scale.

This is why CODESYS familiarity matters more than feature lists.

CODESYS as a Familiar Engineering Environment

CODESYS is widely adopted across industrial automation, PLCs, and mobile control systems.

For system integrators, this means:

  • No need to retrain teams for each display vendor

  • Established IEC 61131-3 workflows (ST, FBD, LD)

  • Consistent project structure across controllers and HMIs

Running a full CODESYS 3.5 runtime alongside high-resolution graphical interfaces, however, requires more than software compatibility—it requires sufficient processing headroom at the hardware level.

Multi-core application architectures allow protocol handling, logic execution, and UI rendering to run in parallel, preserving deterministic behavior even under load.

CODESYS 3.5 running on a CAN bus display for mobile machinery system integration

Streamlining J1939 Data Mapping with CODESYS in Mobile Machinery

Handling J1939 data is a core task in mobile machinery HMIs.

Within a CODESYS environment, J1939 integration benefits from:

  • Structured variable mapping

  • Reusable function blocks for PGN and SPN handling

  • Clear separation between communication logic and UI behavior

This approach avoids scattered, hard-coded parsing logic and makes J1939 handling transparent and maintainable—especially when machine variants introduce new ECUs or parameter sets.

For integrators managing multiple OEM platforms, this structure significantly reduces commissioning and debugging time.

Logic Reuse Across Machine Platforms

Profitability for system integrators depends on reuse.

With CODESYS-based CAN bus displays, integrators can:

  • Build shared libraries for common machine functions

  • Reuse logic across display and controller projects

  • Maintain consistent operator behavior across product families

This reuse model is far more efficient than rebuilding UI logic from scratch for each display model.

Integrating Display Logic into a Distributed Control Architecture

Modern mobile machinery increasingly adopts distributed control architectures.

When a CAN bus display supports CODESYS and provides sufficient local resources, it can:

  • Handle operator interaction logic locally

  • Process local sensor inputs

  • Control auxiliary outputs without involving the main vehicle controller

With up to 20 inputs and 8 outputs available directly on the display unit, system integrators can offload localized logic to the HMI, reducing controller complexity and CAN traffic.

This transforms the display from a visualization endpoint into an active logic node.

Simplifying Commissioning and Debugging

Commissioning often determines whether a project stays profitable.

CODESYS-based displays support:

  • Online monitoring of variables

  • Structured debugging tools

  • Clear signal traceability from CAN input to UI output

When issues occur—missing J1939 data, incorrect UI states, or timing conflicts—integrators can debug within a familiar environment instead of relying on vendor-specific utilities.

Supporting Long-Term Maintenance and Lifecycle Changes

Mobile machinery platforms frequently remain in service for many years.

During this lifecycle:

  • Software teams change

  • ECUs are updated

  • Features are added incrementally

Displays with ample onboard memory and storage allow integrators to maintain complex CODESYS projects, store documentation, and retain historical data directly on the device.

This simplifies updates and reduces dependency on external systems during field service.

Linux-Based CODESYS Displays for High-Performance HMIs

Many modern CAN bus displays are built on Linux-based platforms.

For system integrators, a Linux-based CODESYS display offers:

  • Higher graphical performance

  • Better multitasking capability

  • Support for complex HMI and video applications

When paired with sufficient CPU and memory resources, this architecture supports advanced HMIs without sacrificing determinism.

Sonnepower SPD Series Advantage

From an engineering standpoint, Sonnepower’s SPD series CAN bus displays provide a balanced platform for CODESYS-based integration:

  • Full support for CODESYS 3.5 runtime

  • High-performance multi-core application architecture

  • Extensive integrated I/O for local logic execution

  • Ruggedized design suitable for mobile machinery environments

These characteristics align closely with the real-world needs of OEM system integrators.

To discuss your system architecture or integration requirements, contact us or send an email to